- Page d'accueil /
- Maison et cuisine /
- Heating, Cooling & Air Quality /
- Parts & Accessories /
- Air Conditioner Parts & Accessories /
- Accessoires /
- 2PCS KLIXON MRA99908-9201 Compressor Overload...
2PCS KLIXON MRA99908-9201 Compressor Overload Protector for Air Conditioner
€ 39
Price Details
Excluding Shipping & Custom charges ( Shipping and custom charges will be calculated on checkout )
*All items will import from États-Unis
QTY:
Ubuy s'engage à protéger votre sécurité et votre confidentialité. Notre système avancé de sécurité des paiements garantit la confidentialité en chiffrant vos informations lors de la transmission grâce aux protocoles AES (Advanced Encryption Standards) et SSL (Secure Socket Layer). Vos coordonnées de paiement sont 100 % sécurisées car nous ne partageons pas vos informations de paiement avec des vendeurs tiers.
The MRA99908-9201 overload and overheat protector provides reliable protection for KLIXON air conditioning compressors.
Livraison
rapide
Retour
gratuit*
Emballage sécurisé
Produits 100 % originaux
Conformité PCI DSS
Certifié ISO 27001
Ce qui se démarque
Détails du produit
| Item Weight | 0.15 lbs (70 grams) |
À qui est-ce destiné ?
-
DIY Homeowners
Ideal for homeowners looking to replace worn-out overload protection in their air conditioning units efficiently and affordably.
-
HVAC Technicians
A great replacement part for professional technicians servicing air conditioners for enhanced performance and reliability.
-
Cost-Conscious Users
Perfect for budget-minded individuals needing effective solutions without the high costs associated with brand-name components.
-
Brand Loyalists
Not suitable for users who prefer only OEM parts from specific air conditioning manufacturers for warranty reasons.
-
Non-Technical Consumers
May not be ideal for individuals lacking technical skills or guidance in installation and troubleshooting of AC units.
-
High-End Systems
Not recommended for premium air conditioning systems requiring specialized components beyond generic overload protectors.
DESCRIPTION DU PRODUIT
2PCS KLIXON MRA99908-9201 Compressor Overload Protector for Air Conditioner
Questions et réponses des clients
-
question:
What is the purpose of the KLIXON MRA99908-9201 Compressor Overload Protector?
répondre: The KLIXON MRA99908-9201 is designed to protect your air conditioner's compressor from overheating and potential damage due to electrical overloads. It acts as a safeguard by interrupting the power supply when the compressor runs excessively hot, thereby preventing costly repairs or replacements. This protector is particularly useful in maintaining the longevity and efficiency of your AC system, ensuring it operates smoothly under heavy workloads, such as during peak summer heat. -
question:
How do I know if my air conditioner's overload protector is failing?
répondre: Signs of a failing overload protector may include inconsistent cooling performance, frequent tripping of the circuit breaker, or the compressor not starting at all. If you notice any unusual noises from the unit or if the air conditioner frequently shuts down, these may indicate that the overload protector is not functioning properly. Regular maintenance checks can help identify these issues early, allowing for preventative actions before major failures occur. -
question:
Can I replace the KLIXON MRA99908-9201 myself?
répondre: Replacing the KLIXON MRA99908-9201 can be a straightforward task for those with basic electrical skills. Ensure you first disconnect power to the unit and consult your air conditioner's manual for specific instructions. If you encounter any uncertainties, it's wise to seek professional assistance to avoid hazards and ensure proper installation, as incorrect handling may cause damage or injury. -
question:
Is the KLIXON MRA99908-9201 compatible with all air conditioners?
répondre: The KLIXON MRA99908-9201 is designed to work with many brands and models of air conditioning units, but compatibility can vary. It's essential to check your air conditioner's specifications and ensure that this overload protector matches the voltage and amperage ratings required for your unit. Always refer to the manufacturer's guidelines or consult with a technician if unsure about compatibility. -
question:
What is the typical lifespan of a compressor overload protector?
répondre: The lifespan of a compressor overload protector, including the KLIXON MRA99908-9201, largely depends on usage patterns and environmental conditions. Typically, these protectors can last several seasons; however, frequent cycling of the compressor, exposure to extreme temperatures, and power surges can diminish their lifespan. Regular inspections can help to determine optimal timing for replacements and ensure your system remains protected. -
question:
How does the KLIXON MRA99908-9201 affect my air conditioner's efficiency?
répondre: By preventing the compressor from overheating, the KLIXON MRA99908-9201 helps maintain your air conditioner's efficiency. A properly functioning overload protector reduces the risk of hard starts that can draw excessive power, thus improving energy consumption. Your AC unit can operate at its intended efficiency level, enhancing cooling performance and lowering energy bills over time. -
question:
What should I do if my air conditioner keeps tripping the overload protector?
répondre: If your air conditioner frequently trips the overload protector, it's important to troubleshoot the cause. Potential issues might include an underperforming compressor, blocked airflow, or electrical problems within the system. Inspecting the air filter, cleaning the condenser coils, and checking the refrigerant levels are good starting points. If these actions don't resolve the issue, consulting a professional technician for further diagnostics is recommended. -
question:
Can the KLIXON MRA99908-9201 be used in commercial HVAC systems?
répondre: The KLIXON MRA99908-9201 is primarily designed for residential systems, but it may be compatible with some smaller commercial HVAC systems, depending on the specifications. It is crucial to verify the power requirements and compatibility with the commercial unit it’s intended for. For larger setups, consulting a HVAC professional for the right specifications and components is advisable to ensure reliable protection. -
question:
Where can I buy 2PCS KLIXON MRA99908-9201 Compressor Overload Protector for Air Conditioner?
répondre: You can purchase the 2PCS KLIXON MRA99908-9201 Compressor Overload Protector for Air Conditioner on Ubuy in Monaco. Ubuy offers a reliable platform for obtaining this product, ensuring that you receive genuine components. It’s essential to buy from trusted retailers for quality assurance and optimal functionality of your air conditioner's protection devices. -
question:
What are the installation steps for the KLIXON MRA99908-9201?
répondre: Installing the KLIXON MRA99908-9201 involves turning off the power to the air conditioning unit, removing the access panel, and identifying the existing overload protector. Disconnect the old protector carefully, noting the wiring connections. Then, connect the new KLIXON protector by reversing the disconnection steps, ensuring secure and correct wiring. Finally, reattach the access panel and restore power to test the installation. Following the manufacturer's guidelines is crucial to ensure a successful installation.
RIKOLOL Accessories Editorial Review
Avis et évaluations clients
-
5 étoile
100%
-
4 étoile
0%
-
3 étoile
0%
-
2 étoile
0%
-
1 étoile
0%
Donnez votre avis sur ce produit
Partagez votre avis avec d'autres clients
Avantages
- Easy to install
- Fits various AC models
- Helps prevent compressor damage
Les inconvénients
- Some users report premature failure.
Historique des prix du produit
Informations importantes
- Limitations : Pour les produits expédiés à l'international, veuillez noter que toute garantie du fabricant peut ne pas être valide ; les options de service du fabricant peuvent ne pas être disponibles ; les manuels, instructions et avertissements de sécurité des produits peuvent ne pas être dans les langues du pays de destination ; les produits (et les matériaux qui les accompagnent) peuvent ne pas être conçus conformément aux normes, spécifications et exigences d'étiquetage du pays de destination ; et les produits peuvent ne pas être conformes à la tension et aux autres normes électriques du pays de destination (nécessitant l'utilisation d'un adaptateur ou d'un convertisseur le cas échéant). Il incombe au destinataire de s'assurer que le produit peut être importé légalement dans le pays de destination. En cas de commande auprès d'Ubuy ou de ses filiales, le destinataire est l'importateur officiel et doit se conformer à toutes les lois et réglementations du pays de destination.
- Tous les produits listés sur Ubuy ne sont pas à vendre, Ubuy étant un moteur de recherche mondial. Les produits sont soumis aux réglementations en matière d'exportation et de commerce.
€ 39
Commandez maintenant et recevez votre commande aux alentours du Vendredi, Juin 26
This item is not restrict in my country.(Please click on above link if this item is not restrict in your country, So our team will review and allow.)
QTY:
Ubuy s'engage à protéger votre sécurité et votre confidentialité. Notre système avancé de sécurité des paiements garantit la confidentialité en chiffrant vos informations lors de la transmission grâce aux protocoles AES (Advanced Encryption Standards) et SSL (Secure Socket Layer). Vos coordonnées de paiement sont 100 % sécurisées car nous ne partageons pas vos informations de paiement avec des vendeurs tiers.
Caractéristiques et avantages
- Reliable protection for KLIXON air conditioning compressors.
- Prevents compressor overload and overheating.
- User-friendly design for easy installation.
- Enhances energy efficiency by reducing excessive load.
- Crafted from durable materials for long-lasting performance.
- Ideal for maintaining operational longevity of the compressor.